Outdoor unit
:
RAS
‐
2M14S3AV
‐
E , -TR
<
Cooling / 220V >
Unit capacity
Total
(kW)
Cooling capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.00
-
-
2.0
400
2.32
(
1.3
-
3.0
) (
260
-
840 ) (
1.54
-
4.09
)
10
-
-
10
2.70
-
-
2.7
640
3.39
(
1.3
-
3.2
) (
260
-
860 ) (
1.54
-
4.18
)
13
-
-
13
3.70
-
-
3.7
1050
5.08
(
1.3
-
3.8
) (
260
-
1150 ) (
1.54
-
5.55
)
2 units
07
07
-
14
2.00
2.00
-
4.0
940
4.56
(
1.6
-
4.5
) (
290
-
1130 ) (
1.71
-
5.45
)
10
07
-
17
2.30
1.70
-
4.0
870
4.23
(
1.6
-
4.6
) (
290
-
1130 ) (
1.71
-
5.45
)
13
07
-
20
2.60
1.40
-
4.0
850
4.14
(
1.6
-
4.7
) (
290
-
1140 ) (
1.71
-
5.50
)
10
10
-
20
2.00
2.00
-
4.0
850
4.14
(
1.6
-
4.7
) (
290
-
1140 ) (
1.71
-
5.50
)
13
10
-
23
2.31
1.69
-
4.0
840
4.09
(
1.6
-
4.8
) (
290
-
1150 ) (
1.71
-
5.55
)
13
13
-
26
2.00
2.00
-
4.0
830
4.04
(
1.6
-
4.9
) (
290
-
1150 ) (
1.71
-
5.55
)
<
Cooling / 230V >
Unit capacity
Total
(kW)
Cooling capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.00
-
-
2.0
400
2.22
(
1.3
-
3.0
) (
260
-
840 ) (
1.47
-
3.91
)
10
-
-
10
2.70
-
-
2.7
640
3.24
(
1.3
-
3.2
) (
260
-
860 ) (
1.47
-
4.00
)
13
-
-
13
3.70
-
-
3.7
1050
4.86
(
1.3
-
3.8
) (
260
-
1150 ) (
1.47
-
5.31
)
2 units
07
07
-
14
2.00
2.00
-
4.0
940
4.36
(
1.6
-
4.5
) (
290
-
1130 ) (
1.64
-
5.22
)
10
07
-
17
2.30
1.70
-
4.0
870
4.05
(
1.6
-
4.6
) (
290
-
1130 ) (
1.64
-
5.22
)
13
07
-
20
2.60
1.40
-
4.0
850
3.96
(
1.6
-
4.7
) (
290
-
1140 ) (
1.64
-
5.26
)
10
10
-
20
2.00
2.00
-
4.0
850
3.96
(
1.6
-
4.7
) (
290
-
1140 ) (
1.64
-
5.26
)
13
10
-
23
2.31
1.69
-
4.0
840
3.91
(
1.6
-
4.8
) (
290
-
1150 ) (
1.64
-
5.31
)
13
13
-
26
2.00
2.00
-
4.0
830
3.87
(
1.6
-
4.9
) (
290
-
1150 ) (
1.64
-
5.31
)
<
Cooling / 240V >
Unit capacity
Total
(kW)
Cooling capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.00
-
-
2.0
400
2.13
(
1.3
-
3.0
) (
260
-
840 ) (
1.41
-
3.75
)
10
-
-
10
2.70
-
-
2.7
640
3.10
(
1.3
-
3.2
) (
260
-
860 ) (
1.41
-
3.84
)
13
-
-
13
3.70
-
-
3.7
1050
4.66
(
1.3
-
3.8
) (
260
-
1150 ) (
1.41
-
5.08
)
2 units
07
07
-
14
2.00
2.00
-
4.0
940
4.18
(
1.6
-
4.5
) (
290
-
1130 ) (
1.57
-
5.00
)
10
07
-
17
2.30
1.70
-
4.0
870
3.88
(
1.6
-
4.6
) (
290
-
1130 ) (
1.57
-
5.00
)
13
07
-
20
2.60
1.40
-
4.0
850
3.79
(
1.6
-
4.7
) (
290
-
1140 ) (
1.57
-
5.04
)
10
10
-
20
2.00
2.00
-
4.0
850
3.79
(
1.6
-
4.7
) (
290
-
1140 ) (
1.57
-
5.04
)
13
10
-
23
2.31
1.69
-
4.0
840
3.75
(
1.6
-
4.8
) (
290
-
1150 ) (
1.57
-
5.08
)
13
13
-
26
2.00
2.00
-
4.0
830
3.71
(
1.6
-
4.9
) (
290
-
1150 ) (
1.57
-
5.08
)
・
The above specification values are those under the conditions that the indoor DB/WB=27/19
℃
and the outdoor DB/WB=35/–
℃
.
Operating
status
Indoor unit
Operating
status
Indoor unit
Operating
status
Indoor unit
FILE NO. SVM-15102
- 18 -