Heating / 220V >
Unit capacity
Total
(kW)
Heating capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.70
-
-
2.7
620
3.34
(
0.9
-
4.3
) (
190
-
1390 ) (
1.13
-
6.66
)
10
-
-
10
4.00
-
-
4.0
1120
5.41
(
0.9
-
4.4
) (
190
-
1360 ) (
1.13
-
6.52
)
13
-
-
13
4.40
-
-
4.4
1260
6.06
(
1.0
-
4.7
) (
190
-
1480 ) (
1.13
-
7.08
)
2 units
07
07
-
14
2.20
2.20
-
4.4
920
4.47
(
1.3
-
5.1
) (
240
-
1270 ) (
1.42
-
6.11
)
10
07
-
17
2.53
1.87
-
4.4
910
4.42
(
1.3
-
5.1
) (
250
-
1250 ) (
1.48
-
6.01
)
13
07
-
20
2.86
1.54
-
4.4
880
4.28
(
1.3
-
5.2
) (
250
-
1250 ) (
1.48
-
6.01
)
10
10
-
20
2.20
2.20
-
4.4
890
4.33
(
1.3
-
5.1
) (
250
-
1230 ) (
1.48
-
5.92
)
13
10
-
23
2.54
1.86
-
4.4
870
4.23
(
1.3
-
5.2
) (
250
-
1230 ) (
1.48
-
5.92
)
13
13
-
26
2.20
2.20
-
4.4
850
4.14
(
1.3
-
5.2
) (
250
-
1220 ) (
1.48
-
5.87
)
<
Heating / 230V >
Unit capacity
Total
(kW)
Heating capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.70
-
-
2.7
620
3.20
(
0.9
-
4.3
) (
190
-
1390 ) (
1.08
-
6.37
)
10
-
-
10
4.00
-
-
4.0
1120
5.17
(
0.9
-
4.4
) (
190
-
1360 ) (
1.08
-
6.24
)
13
-
-
13
4.40
-
-
4.4
1260
5.80
(
1.0
-
4.7
) (
190
-
1480 ) (
1.08
-
6.77
)
2 units
07
07
-
14
2.20
2.20
-
4.4
920
4.27
(
1.3
-
5.1
) (
240
-
1270 ) (
1.36
-
5.84
)
10
07
-
17
2.53
1.87
-
4.4
910
4.23
(
1.3
-
5.1
) (
250
-
1250 ) (
1.42
-
5.75
)
13
07
-
20
2.86
1.54
-
4.4
880
4.09
(
1.3
-
5.2
) (
250
-
1250 ) (
1.42
-
5.75
)
10
10
-
20
2.20
2.20
-
4.4
890
4.14
(
1.3
-
5.1
) (
250
-
1230 ) (
1.42
-
5.66
)
13
10
-
23
2.54
1.86
-
4.4
870
4.05
(
1.3
-
5.2
) (
250
-
1230 ) (
1.42
-
5.66
)
13
13
-
26
2.20
2.20
-
4.4
850
3.96
(
1.3
-
5.2
) (
250
-
1220 ) (
1.42
-
5.62
)
<
Heating / 240V >
Unit capacity
Total
(kW)
Heating capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.70
-
-
2.7
620
3.07
(
0.9
-
4.3
) (
190
-
1390 ) (
1.04
-
6.11
)
10
-
-
10
4.00
-
-
4.0
1120
4.96
(
0.9
-
4.4
) (
190
-
1360 ) (
1.04
-
5.98
)
13
-
-
13
4.40
-
-
4.4
1260
5.55
(
1.0
-
4.7
) (
190
-
1480 ) (
1.04
-
6.49
)
2 units
07
07
-
14
2.20
2.20
-
4.4
920
4.10
(
1.3
-
5.1
) (
240
-
1270 ) (
1.30
-
5.60
)
10
07
-
17
2.53
1.87
-
4.4
910
4.05
(
1.3
-
5.1
) (
250
-
1250 ) (
1.36
-
5.51
)
13
07
-
20
2.86
1.54
-
4.4
880
3.92
(
1.3
-
5.2
) (
250
-
1250 ) (
1.36
-
5.51
)
10
10
-
20
2.20
2.20
-
4.4
890
3.97
(
1.3
-
5.1
) (
250
-
1230 ) (
1.36
-
5.43
)
13
10
-
23
2.54
1.86
-
4.4
870
3.88
(
1.3
-
5.2
) (
250
-
1230 ) (
1.36
-
5.43
)
13
13
-
26
2.20
2.20
-
4.4
850
3.79
(
1.3
-
5.2
) (
250
-
1220 ) (
1.36
-
5.38
)
・
The above specification values are those under the conditions that the indoor DB/WB=20/-
℃
and the outdoor DB/WB=7/6
℃
.
Operating