Pressure
measurement
P
Gauge attaching port
connecting port
Packed valve
(Liquid side)
(dia.6,35)
Sectional shape
of heat insulator
Connecting pipe
Thickness : 0,8mm
dia.9,52
Packed valve
(Gas side)
(dia.9,52)
Packed valve
(Gas side)
(dia.9,52)
Connecting pipe
Thickness : 0,8mm
dia.6,35
Packed valve
(Liquid side)
(dia.6,35)
Outdoor unit
Refrigerant amount : 1,32kg (R410A)
TE
TO
Propeller fan
T2
Temp.measurement
TD
Compressor
DA136A1T-40N
High pressure
switch
TS
TGa
TGb
To
B room
To
B room
Pulse motor valve
at liquid side
(dia.1,6)
Al
lo
w
ab
le
h
ei
g
ht
di
ff
er
en
ce
:
1
5
m
Al
lo
w
ab
le
p
ip
e
le
ng
th
Cross flow fan
TA
Indoor unit A
T1
Temp. measurement
TC
Evaporator
・RAS-2M18S3AV-E ,
-A , -TR
・RAS-
2M14S3AV-E
, -TR
NOTE :
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
NOTE :
• You need not add refrigerant if the piping length is
30
m or less.
• Connection of only one indoor unit is unavailable. Two indoor units should be connected.
FILE NO. SVM-15102
- 3
7
-
Per 1 unit
Max. : 20m
Min. : 2m
Total
Max. : 30m