e-STUDIO350/450 GENERAL OPERATION
4 - 2
November 2003 © TOSHIBA TEC
4
4.2.2 Ready state (ready for copying)
•
Buttons on the control panel enabled
•
When no button is pressed for a certain period of time,
– Set number “1” and reproduction ratio “100%” are displayed. Equipment returns to the normal
ready state.
4.2.3 Drawer feed copying (Upper drawer paper feeding)
(1)
Press the [START] button
•
“READY” changes to “COPYING”
•
Exposure lamp ON
•
Scan motor ON
→
carriages -1 and -2 move forward
•
Polygonal motor rotates in high speed
•
Main motor and exit motor ON
– The drum, fuser unit, developer unit and exit roller are driven.
(2)
Drawer paper feeding
•
Main charger, developer bias and discharge LED ON
•
Fans are rotated in high speed
•
Drawer feed clutch ON
– The pickup roller, feed roller, separation roller and transport roller start to rotate.
•
Paper reaches the upper drawer feed sensor
– The upper drawer feed sensor is turned ON.
•
Paper reaches the registration roller.
– The registration sensor is turned ON and aligning is performed.
•
Drawer feed clutch OFF after a certain period of time
(3)
After the carriage operation:
•
Registration clutch ON after a certain period of time
→
paper is transported to the transfer area.
•
Copy counter operates
(4)
After the registration clutch is turned ON:
•
Transfer charger ON after a certain period of time
(5)
Completion of scanning
•
Scan motor OFF
•
Exposure lamp OFF
•
Registration clutch OFF (after the trailing edge of the paper passed the registration roller)
•
“READY (PRINTING)” is displayed
Summary of Contents for e-STUDIO350
Page 2: ... 2003 TOSHIBA TEC CORPORATION All rights reserved ...
Page 94: ...e STUDIO350 450 GENERAL OPERATION 4 16 November 2003 TOSHIBA TEC 4 ...
Page 182: ...e STUDIO350 450 PAPER FEEDING SYSTEM 9 32 November 2003 TOSHIBA TEC 9 ...
Page 188: ...e STUDIO350 450 DRIVE SYSTEM 10 6 November 2003 TOSHIBA TEC 10 ...
Page 208: ...e STUDIO350 450 DRUM RELATED SECTON 11 20 November 2003 TOSHIBA TEC 11 ...
Page 224: ...e STUDIO350 450 DEVELOPMENT SYSTEM 12 16 November 2003 TOSHIBA TEC 12 ...
Page 270: ...e STUDIO350 450 AUTOMATIC DUPLEXING UNIT 14 20 November 2003 TOSHIBA TEC 14 ...
Page 278: ...e STUDIO350 450 POWER SUPPLY UNIT 15 8 November 2003 TOSHIBA TEC 15 ...
Page 279: ...November 2003 TOSHIBA TEC 16 1 e STUDIO350 450 PC BOARDS 16 16 PC BOARDS 1 PWA F SYS ...
Page 280: ...e STUDIO350 450 PC BOARDS 16 2 November 2003 TOSHIBA TEC 16 2 PWA F LGC ...
Page 283: ...November 2003 TOSHIBA TEC 16 5 e STUDIO350 450 PC BOARDS 16 9 PWA F DSP 10 PWA F KEY ...
Page 285: ......
Page 286: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8442 JAPAN ...