9168 Control Box
P/N 7010-0781
7-13
Problem
Elevation Control key displays:
“Waiting for Initialization”
Causes
Solutions
The MC-2.5 Receiver
Box has not been
successful tracking
enough valid satellites.
Check that the rover GPS antenna has a
clear view of the sky.
Check for obstructions, such as trees,
buildings, and vehicles, that can block or
reflect satellite signals.
The system is still in
the process of
determining a solid
position.
If this is the very first time for operation,
this message may persist for several
minutes while the Legacy-E+ or Hiper Lite
obtains a new almanac.
Problem
Elevation Control key displays:
“Out of design area”
Causes
Solutions
The machine is out of
the Design Surface
area.
Make sure that the correct Control Point
File and Design Surface file is selected.
Move into the Design Surface area so the
operator can start grading.
Problem
Elevation Control key displays :
“No GPS localization”
Causes
Solutions
The Control Points file
currently selected has
not been localized
properly.
Make sure that the correct Control Point
file currently is selected.
Summary of Contents for mmGPS 3D Paver
Page 1: ...MM 03 0AVER 2EFERENCE ANUAL...
Page 2: ......
Page 4: ...ECO 3067...
Page 34: ...Introduction mmGPS 3D Paver Reference Manual Notes 1 20...
Page 70: ...Setting up the Jobsite and Pocket 3D mmGPS 3D Paver Reference Manual Notes 2 36...
Page 208: ...Getting Started mmGPS 3D Paver Reference Manual Notes 5 32...
Page 252: ...Safety Information mmGPS 3D Paver Reference Manual Notes A 4...
Page 278: ...Glossary mmGPS 3D Paver Reference Manual Notes E 6...
Page 285: ...Index P N 7010 0781 Index definition 3 23 display options 3 25...
Page 286: ...mmGPS Paver 3D Reference Manual Notes Index...
Page 287: ......