Ver1.3
,
05/18/2005
,~
1
~
SG-3016 Isolated Strain Gauge Input Module
User’s Manual
Introduction
The SG-3016 is a voltage input to voltage or current output signal conditioning module. It has
3000Vdc three-way isolation for input, output and power. And can change the input/output
range via internal configuration switches.
The SG-3016 has an LED display to show whether the SG-3016 is functioning
correctly and
has three VRs (Zero, Span, Exci) to calibrate the input/output range accuracy.
The bandwidth of the SG-3016 is typically 600Hz. It’s easy to mount the SG-3016 on a
standard DIN rail and can operate in environments with wide temperature range.
Specifications
Voltage Specifications:
Electrical input: ±10mV, ±20mV, ±30mV, ±50mV, ±100mV
Excitation voltage: 1 ~10Vdc (20mA max.)
Voltage output:
Bipolar: ±5V, ±10V
Unipolar: 0~5V, 0~10V
Output impedance: <50
Ω
Current output:
Current: 0~20mA
Current load resistor:0~500
Ω
(Source)
General
Three-way isolation: 3000Vdc
Accuracy: ±0.1% of full range
Bandwidth: 600Hz (typical)
@
-
3dB
Operation temperature range:-25
°
C
~
75
°
C
Storage temperature range:-30
°
C
~
85
°
C
Supply Voltage
Input Range: 10~30Vdc
Consumption: 1.44W (voltage output)
1.74W (current output)
configure
The terminal wiring for the SG-3016 is shown in Figure A. Positive power terminals pin’s 7 and
9 are internally connected, as are negative pins 10 and 12. Power can be connected through
the adjacent modules, making wiring much easier. The SG-3016 uses a power input range of
10~30Vdc.
Table 1 and table 2 show the switch positions used to configure the input and output range.
The I/O configuration switches are located inside the module. And can be accessed by
removing the DIN-rail bracket covers by sliding them in the direction shown in Figure B.