14.
Parameters
5-21
5. Operations and
adjustment
TSC
24
Threshold judgment range
[Select]
Invalid/Valid
Invalid
Description
When performing the torque determination in pressing operation,
Valid:
Sets the judgment range.
Invalid: Does not set the judgment range.
25
Default standstill mode
[Select] Invalid/Automatic turn off 1 to 3/
Full servo
Invalid
Description
Sets the default value of "Standstill mode" after reaching the target position of each
STEP. Selecting an appropriate mode reduces heat generation and power usage.
Invalid : The servo turns OFF but No. 11 current continues to flow.
Automatic turn OFF 1: After the elapse of the time in No. 17, the servo turns OFF and the
flowing current becomes 0.
Automatic turn OFF 2: After the elapse of the time in No. 18, the servo turns OFF and the
flowing current becomes 0.
Automatic turn OFF 3: After the elapse of the time in No. 19, the servo turns OFF and the
flowing current becomes 0.
Full servo: The servo is always turned ON even in stop status.(The current increases or
decreases depending on the external force)
26
Ball screw lead
mm
0.0 to 99.9
Depends on
models
Description Sets the length of ball screw lead. A value tailored to the actuator is set before shipment.
28
Cur. select at miss
[Select] Current limit on stop status/Limit
for pressing
Current limit on
stop status
Description
Sets the current limit after the pressing operation being in vain.
Current limit on stop status: Current set in No. 11
Limit for pressing:
Current set in "Push (%)"
29
Max. speed
mm/s
1 to 1000
Depends on
models
Description Sets the maximum speed settable in the "Program table."
30
Position deviation
mm
0.00 to 999.99
Depends on
models
Description Sets the value to output alarm code No. 32 (Excessive position error (deviation)).
*31
Inching distance
mm
0.1 to 200.0
10.0
Description D-STEP: Sets the inching distance on the PROGRAM screen.
For the distance setting by I/O input, see No. 22.
Note: The parameter with "*" attached to "No." can be changed while keeping the servo ON.
Note: [Select] in the "Unit" field is selected from the items displayed in "Setting range."
No.
Parameter name
Unit
Setting range
Default value
23
Judgment time
ms
1
to
99999
10
Description When performing the torque determination in pressing operation, this sets the time until
the condition is judged to be met after reaching the threshold.
Summary of Contents for TSC Series
Page 98: ...MEMO ...