3. Wiring
1.
How to wire
3-6
TSC
Use one machine of TSC (with reset switch)
・
Even if the emergency stop switch is released, the motor would not be energized until the
reset switch is turned ON.
・
The reset switch must be turned ON when the power is turned ON.
・
Use the external relay CR with the surge absorption diode at 0.1 A or less coil current.
・
Connecting TDO will open the internal relay K1, and the TDO emergency stop switch is
activated.
・
When TDO is not connected, the internal relay K1 will be closed.
・
When connecting TSC to the network unit TNU, do not wire the CN5 pin number
①
(S1).
(Doing so may cause fault.)
24V
0V
①
S1
②
S2
③
MPO
④
MPI
⑤
24V
⑥
0V
⑦
EMG-
TDO
0V
Emergency
stop switch
CN4
CN3
K1
TSC
CR
X
X
CR
CR
Reset
switch