3. Wiring
1.
How to wire
3-3
TSC
1-1
Entire wiring
See the wiring example below.
The cable that connects to the CN1, CN3, and CN5 connectors with
★
mark is not provided,
please prepare it separately.
(
→
P.3-4)
The optional cable (CBL-COM-03) to connect to CN3 PC and optional I/O cable (CBL-TSC-IO)
to CN1 are available.
(
→
P.2-5)
TDO(
→
*1)
PC (D-STEP) (
→
*2)
Higher device
Emergency stop switch
(This should be prepared
by yourself. )
(
→
P. 3-12)
Driver controller TSC
The actuator cable is provided
with the actuator unit.
(→*3)
* To use a 10m actuator cable,
please insert a noise filter.
Recommended noise filter is
“RSAN-2003 (made by TDK-
Lambda Corporation)”.
★
I/O connector for CN1 is
provided with TSC.
I/O cables are provided as
an option.
(→P. 2-5)
★
★
★
The power supply
should be prepared by
yourself. Power connector
is provided with TSC.
(→ P.3-4)
CN1
CN2
CN4
CN3
CN5
Actuator
PC communication
cables are provid-
ed as an option.
(
→
P. 2-5)
★
*3: See the separate ES/EC instruction manual.
*1: See the separate TDO Instruction Manual.
*2: See the separate D-STEP instruction manual.
24V DC power
Summary of Contents for TSC Series