7.
Positioning operation
5-12
5. Operations and
adjustment
TSC
7-1
Positioning operation
You can perform this in all operation modes.
When "Push (%)" in the program table is "0," positioning operation will be performed to move the
actuator to the target "Position."
The INPS output (pin.30) is turned ON when the current position enters into the "IN-POSI" of the
target "POSI."
For more information on settings, see the separate D-STEP or TDO Instruction Manual.
STEP No.
ABS / INC
Position
Speed
ACC
DCC
JUMP
Comment
[mm]
[mm/s]
[mm/s
2
]
[mm/s
2
]
[No.]
0
ABS
70.00
80
3
3
1
Positioning operation 1
1
ABS
100.00
30
3
3
E
Positioning operation 2
Speed
30mm/s
Position
100mm
Target
position 1
80mm/s
70mm
Target
position 0
* Some of the setting fields are omitted.
Example
STEP No.0
STEP No.1
Summary of Contents for TSC Series