1.
Operation mode
5-5
5. Operations and
adjustment
TSC
• There are 2 types of TSC operation mode: the MANUAL mode connects the PC to
CN3 to operate the mode change switch with MANU, and the AUTO mode connects
the external input and output signals to CN1 to operate the mode change switch
with AUTO.
• In description of operations in this chapter,
①
AUTO mode, and
②
external input
and output are used unless otherwise stated.
1-1
MANUAL mode
Operations are performed with the mode change switch set to MANU in this mode.
MANU S output (pin.28) is turned ON.
In this mode, you can use the setup tool D-STEP on the connected PC to perform input and ex-
ecution of the operation programming, parameter setting, manual jog and inching operations, etc.
For more information, see the separate D-STEP or TDO Instruction Manual.
1-2
AUTO mode
Operations are performed with the mode change switch set to AUTO in this mode.
MANU S output (pin.28) is turned OFF.
This manual primarily describes the operation method and operations using the external input
and output signals in AUTO mode.
Operations must be programmed beforehand.
See the separate setup tool D-STEP Instruction Manual.
In the descriptions, "on" and "ON" means the external input and output terminal is shorted to 0 V.
1-3
MANUAL mode switching
In the AUTO mode, turning MANU (pin.14) ON will also switch to the MANUAL mode.
When switching is done, MANU S output (pin.28) is turned ON.
When the parameter No.38 (Inhibit MANU input)
(
→
P.5-22)
( is set to "Valid," MANU input is re-
jected.
When first energizing or adjusting unit start-up, setting a small value to the parameter No.20 (Speed
ov
e
rride)
(
→
P.5-20)
limits the speed temporarily and you can ensure the safety.
Reference
Auto
Manual/Auto switching
Manual
ON
Operation mode status "MANU S"
OFF
Accept input
Start accepting I/O input
Inhibit input
T1
T1: 1500 ms