2-11
2.
How to install
2. Installation
TSC
2-2-2
How to install
Use the 2 mounting holes on the fittings of the driver controller TSC and fixing bolts for installa-
tion. Installation direction is vertical only (panel display is upright). Do not perform tilt, horizontal,
or up-side-down installation which disturbs heat discharge.
To prevent effects of the PWM switching noise and external noise, be sure to perform single point
D-type ground for the TSC frame ground (FG).
* Prepare bolts and tools to be used separately.
Fixing bolt
: Cross-recessed pan-head screws or hexagonal-socket-head type bolts M4 x 8
(2 pcs.)
Tools to use
: According to bolt types
<Installation to the front>
Control panel
Cross-recessed pan-head screw M4 x 8
or
Hexagonal-socket-head type bolt M4 x 8