5-15
Tetra Pak
Hoyer
CN 03 E A 01
CUP DISPENSER
###°
CONSENT
:
#
START
:
###°
CUP RELEASE
: ON=###
OFF=###
CUP VACUUM
: ON=###
OFF=###
CUP BLOW VACUM : ON=###
OFF=###
CUP BLOW
: ON=###
OFF=###
4/22
TUBE DISPENSER
###°
CONSENT
:
#
START
:
###°
TUBE RELEASE
: ON=###
OFF=###
TUBE GRIPPER
: ON=###
OFF=###
TUBE DOWN : ON=###
OFF=###
5/22
To set or edit the data, follow the instructions
provided in
“INSTRUCTIONS ON THE USE
OF THE OPERATOR PANEL TO EDIT OR
ENTER DATA”.
Go to page 4/22 by pressing
pdown
The following items are shown:
CONSENT : If this value is set to 1, it allows
automatic operation of the station.
Set this value to 1 if automatic operation of the
CUP DISPENSER station is required.
START:Angular value that allows enabling of
the station during automatic start, and disabling
during automatic stop. The value must always be
lower than or equal to the lowest of the values set
on this page.
CUP RELEASE: Parameters relative to the
cylinders that control the opening/closure of the
cup-stop blades. Set ON and OFF values.
CUP VACUUM: Parameters relative to the
enabling/disabling of the vacuum on suction
cups. Set ON and OFF values.
CUP BLOW VACUUM: Parameters relative to
the enabling/diabling of the air blow which allows
detaching the cup from the suction cup. The blow
must occur when the cup is placed in the lamella
slot.
Set ON and OFF values.
CUP BLOW: Parameters relative to the opening/
closure of the valve that blows air into the cup
magazine to aid cups to leave the stack. This
action normally occurs after the blades release
the cups. Set ON and OFF values.
To set or edit the data, follow the instructions
provided in
“INSTRUCTIONS ON THE USE
OF THE OPERATOR PANEL TO EDIT OR
ENTER DATA”.
Go to page 5/22 by pressing
pdown
The following page is displayed:
The following items are shown:
CONSENT :
If this value is set to 1, it allows
automatic operation of the station.
Set this value to 1 if automatic operation of the
TUBE DISPENSER station is required.
START:
Angular value that allows enabling
of the station during automatic start, and disabling
during automatic stop. The value must always be
lower than or equal to the lowest of the values set
on this page.
TUBE RELEASE:
Parameters relative to the
cylinders that control the opening/closure of the
Summary of Contents for HOYER COMET N
Page 84: ...Tetra Pak Hoyer ...
Page 93: ...Tetra Pak Hoyer 1 3 2 4 5 3 1 2 4 1 1 2 4 13400324 9 12 M 221869 ...
Page 97: ...Tetra Pak Hoyer 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 4 4 13400324 9 18 M 221869 ...
Page 101: ...Tetra Pak Hoyer 3 2 2 3 8 7 6 8 9 5 4 1 9 2 4 13040657 9 24 M 221869 ...
Page 103: ...Tetra Pak Hoyer 4 5 6 6 7 8 4 1 2 3 5 6 6 7 8 9 9 9 9 3 4 13040657 9 27 M 221869 ...
Page 105: ...Tetra Pak Hoyer 1 2 4 3 6 3 12 7 6 8 5 8 5 9 10 11 13 4 12 14 4 4 13040657 9 30 M 221869 ...
Page 121: ...Tetra Pak Hoyer 6 4 5 5 4 3 5 4 5 4 1 2 7 8 9 5 4 10 1 1 13040332 9 54 M 221869 ...
Page 125: ...Tetra Pak Hoyer 2 3 6 4 5 8 7 9 10 11 12 5 5 12 5 1 7 9 14 13 15 1 1 13040046 9 60 M 221869 ...
Page 145: ...Tetra Pak Hoyer 1 2 1 3 3 13040656 9 90 M 221869 ...
Page 150: ...Tetra Pak Hoyer CN 02 LA 02 Comet N Serial number ANNEXES ...