![Tetra Pak HOYER COMET N Manual Download Page 16](http://html.mh-extra.com/html/tetra-pak/hoyer-comet-n/hoyer-comet-n_manual_1092892016.webp)
3-7
Tetra Pak
Hoyer
CN 03 C A 01
Fig. 3.10
5800
2215
1453
3.7 Technical data
3.6.
Demolition and disposal
Useful information on the disposal of the
machinery and its components.
The demolition must be carried out be specialized
personnel equipped with personal and general
prevention means in respect of the safety and
environmental regulations.
Building materials:
- steel, stainless steel, aluminium, cast iron
- copper or silver for electric components
- rubber, nylon, PVC, resins and fibres.
No component is either toxic or harmful.
Special care is needed when disposing of the
ratio motors since they are full of oil.
Do not abandon them in the environment and do
not dispose of them as waste.
WARNING!
Both machinery and
components, at the end of their period of use are
to be disposed of in respect of the regulations
according to the issue in force in the country of
use.
3.5.
Improper uses
Notwithstanding the equipment of the machine
with several safety systems, the operators must
pay attention in order not to cause potentially
dangerous situations for their own and other
people’s safety.
The machine is designed and built for the
exclusive use as indicated in chapter 3.1. Any
other use is to be considered improper and
therefore unreasonable. The builder cannot be
considered responsible for any damage caused
by improper, wrong or unreasonable uses.
All the people who operate the machine have to
be trained suitably on the exact working methods
and they must be informed on the nature and
function of the safety devices.
Standard power supply
220 - 440 V / 3 Ph / 50-60 Hz
Installed power
Main motor: 3 kW
Conveyor motor: 0.18 kW
Total installed power: 5.5 kW
Net weight:
4000 Kg
Gross weight:
5000 Kg
Compressed air
Supply pressure: min 6 bar
Consumption: 1300 Nl/min
Diameter of the supply tube: 3/4" gas
Dimensions
See figure 3.2
Noise
Equivalent level of weighted acoustic pressure A
at 1 meter: 67.5 dBA
Max. pressure of instantaneous weighted acoustic
pressure C in workstations: below 130 dB/
20uPa.
Summary of Contents for HOYER COMET N
Page 84: ...Tetra Pak Hoyer ...
Page 93: ...Tetra Pak Hoyer 1 3 2 4 5 3 1 2 4 1 1 2 4 13400324 9 12 M 221869 ...
Page 97: ...Tetra Pak Hoyer 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 4 4 13400324 9 18 M 221869 ...
Page 101: ...Tetra Pak Hoyer 3 2 2 3 8 7 6 8 9 5 4 1 9 2 4 13040657 9 24 M 221869 ...
Page 103: ...Tetra Pak Hoyer 4 5 6 6 7 8 4 1 2 3 5 6 6 7 8 9 9 9 9 3 4 13040657 9 27 M 221869 ...
Page 105: ...Tetra Pak Hoyer 1 2 4 3 6 3 12 7 6 8 5 8 5 9 10 11 13 4 12 14 4 4 13040657 9 30 M 221869 ...
Page 121: ...Tetra Pak Hoyer 6 4 5 5 4 3 5 4 5 4 1 2 7 8 9 5 4 10 1 1 13040332 9 54 M 221869 ...
Page 125: ...Tetra Pak Hoyer 2 3 6 4 5 8 7 9 10 11 12 5 5 12 5 1 7 9 14 13 15 1 1 13040046 9 60 M 221869 ...
Page 145: ...Tetra Pak Hoyer 1 2 1 3 3 13040656 9 90 M 221869 ...
Page 150: ...Tetra Pak Hoyer CN 02 LA 02 Comet N Serial number ANNEXES ...