![Tetra Pak HOYER COMET N Manual Download Page 29](http://html.mh-extra.com/html/tetra-pak/hoyer-comet-n/hoyer-comet-n_manual_1092892029.webp)
5-9
Tetra Pak
Hoyer
CN 03 E A 01
F15
START/STOP SEALING UNIT (Page 2)
Starts or stops foil sealing if enabled by the
current format.
F16
START/STOP SPRAYING
CHOCOLATE (Page 1)
Starts or stops spraying chocolate if enabled by
the current format.
F16
:
START/STOP LID FEED 1 (Page 2)
Starts or stops loading lids 1 enabled by the
current format.
F17
:
F17: START/STOP DOSER 1
Starts or stops doser 1 if enabled by the current
format.
F17
:
START/STOP LID FEED 2 (Page 2)
Starts or stops loading lids 2 if enabled by the
current format.
F18
: START/STOP DOSER 2 (Page 1)
Starts or stops doser 2 if enabled by the current
format.
F18
:
START/STOP CRIMPER (Page 2)
Starts or stops the crimper if enabled by the
current format.
F19
:
START/STOP PENCIL FILLER (Page
1)
Starts or stops the pencil filler if enabled by the
current format.
F19
:
START/STOP DATER (Page 2)
Starts or stops date stamp if enabled by the
current format.
F20
:
START/STOP TOPPING (Page 1)
Starts or stops topping if enabled by the current
format.
F20
:
START/STOP PICK & PLACE
(Page 2)
Starts or stops the pick & place device if enabled
by the current format.
F21
:
START/STOP PRODUCT EJECTION
(Page 2)
Starts or stops product ejection if enabled by the
current format.
F11
:
RESET
Resets alarms, broken microswitches, inverter
malfunctions, etc.
When an alarm occurs, an “ALARMS” page is
diplayed on the panel, which indicates which
alarm is present. If additional information is
available for a given malfunction, the led of the
help
key will flash.
Press the key to display the information on the
alarm.
Once the alarm is displayed, a technician must
check and repair the problem as necessary. Press
RESET on the display to remove the alarm from
the display.
To use keys F12 through F22 use the 2 pages of
the function keys. Access the first page by
pressing
clr
, the second by pressing
pdown
.
To go back to the first page press
pdup
.
F12
:
START/STOP CONE FEED (Page 1)
Starts or stops loading cones if enabled by the
current format.
F12
:
START/STOP DRY NUT (Page 2)
Starts or stops the dry product dispenser if
enabled by the current format.
F13
:
START/STOP CUP FEED (Page 1)
Starts or stops loading cups if enabled by the
current format.
F13
:
START/STOP COCOA/BALL
DISPENSER (Page 2)
Starts or stops the cocoa or ball dispenser if
enabled by the current format.
F14
:
START/STOP TUBE FEED (Page 1)
Starts or stops the tube loading if enabled by the
current format.
F14
:
START/STOP FOIL DISPENSER (Pa-
ge 2)
Starts or stops the foil dispenser if enabled by
the current format.
F15
START/STOP WAFER FEED (Page 1)
Starts or stops loading wafers if enabled by the
current format.
Summary of Contents for HOYER COMET N
Page 84: ...Tetra Pak Hoyer ...
Page 93: ...Tetra Pak Hoyer 1 3 2 4 5 3 1 2 4 1 1 2 4 13400324 9 12 M 221869 ...
Page 97: ...Tetra Pak Hoyer 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 4 4 13400324 9 18 M 221869 ...
Page 101: ...Tetra Pak Hoyer 3 2 2 3 8 7 6 8 9 5 4 1 9 2 4 13040657 9 24 M 221869 ...
Page 103: ...Tetra Pak Hoyer 4 5 6 6 7 8 4 1 2 3 5 6 6 7 8 9 9 9 9 3 4 13040657 9 27 M 221869 ...
Page 105: ...Tetra Pak Hoyer 1 2 4 3 6 3 12 7 6 8 5 8 5 9 10 11 13 4 12 14 4 4 13040657 9 30 M 221869 ...
Page 121: ...Tetra Pak Hoyer 6 4 5 5 4 3 5 4 5 4 1 2 7 8 9 5 4 10 1 1 13040332 9 54 M 221869 ...
Page 125: ...Tetra Pak Hoyer 2 3 6 4 5 8 7 9 10 11 12 5 5 12 5 1 7 9 14 13 15 1 1 13040046 9 60 M 221869 ...
Page 145: ...Tetra Pak Hoyer 1 2 1 3 3 13040656 9 90 M 221869 ...
Page 150: ...Tetra Pak Hoyer CN 02 LA 02 Comet N Serial number ANNEXES ...