5-14
Tetra Pak
Hoyer
CN 03 E A 01
GENERAL PARAMETERS
###°
SAFETY CAM : ON=###
OFF=###
2/22
CONE DISPENSER
###°
CONSENT
:
#
START
:
###°
CONE RELEASE
: ON=###
OFF=###
CONE DOWNLOAD : ON=###
OFF=###
WAFER CONTROL : ON=###
OFF=###
CONE BLOW
: ON=###
OFF=###
3/22
This page displays the current position in machine
degrees (###°-value at top right) and the
parameters relative to the safety cam (SAFETY
CAM).
The safety cam represents the angular interval
during which, for safety reasons, it is impossible
to perform vertical movements of the stations, as
the lamella belt, by effect of the jogging device,
is moving.
Outside this interval, the belt is still, and all
movements and operations associated to the
working stations on the machine are possible.
If a working station which performs vertical
movements is not in the highest position within
the safety cam, the machine inverter immediately
stops the belt.
We recommend you do not modify the ON and
OFF interval of the safety cam, or the machine
will stop.
NOTE: All the parameters expressed in degrees
refer to the angular position of the machine.
The settings relative to the vertical movement of
each station must be performed so the station
moves downward while the belt is not moving.
Go to page 3/22 by pressing
pdown
.
The following page is displayed:
The following items are shown:
CONSENT : If this value is set to 1, it allows
automatic operation of the station.
Set this value to 1 if automatic operation of the
CONE DISPENSER station is required.
START:Angular value that allows enabling of
the station during automatic start, and disabling
during automatic stop. The value must always be
lower than or equal to the lowest of the values set
on this page.
CONE RELEASE: Parameters relative to the
cylinders that control the opening/closure of the
cone-stop blades. Set ON and OFF values.
CONE DOWNLOAD: Parameters relative to
the enabling/disabling of the rotational actuator
which aids separation of the wafers. Set ON and
OFF values.
WAFER CONTROL: Parameters relative to the
opening/closure of the cone magazine which
allows the cones to fall into the lamella slots.
Set ON and OFF values.
CONE BLOW: Parameters relative to the
opening/closure of the valve that blows air into
the cone magazine to aid cones to leave the stack.
This action normally occurs after the blades
release the cone. Set ON and OFF values.
Current position: A degree field (###º) makes it
possible to display the current machine position
in order to enter suitable data.
Summary of Contents for HOYER COMET N
Page 84: ...Tetra Pak Hoyer ...
Page 93: ...Tetra Pak Hoyer 1 3 2 4 5 3 1 2 4 1 1 2 4 13400324 9 12 M 221869 ...
Page 97: ...Tetra Pak Hoyer 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 4 4 13400324 9 18 M 221869 ...
Page 101: ...Tetra Pak Hoyer 3 2 2 3 8 7 6 8 9 5 4 1 9 2 4 13040657 9 24 M 221869 ...
Page 103: ...Tetra Pak Hoyer 4 5 6 6 7 8 4 1 2 3 5 6 6 7 8 9 9 9 9 3 4 13040657 9 27 M 221869 ...
Page 105: ...Tetra Pak Hoyer 1 2 4 3 6 3 12 7 6 8 5 8 5 9 10 11 13 4 12 14 4 4 13040657 9 30 M 221869 ...
Page 121: ...Tetra Pak Hoyer 6 4 5 5 4 3 5 4 5 4 1 2 7 8 9 5 4 10 1 1 13040332 9 54 M 221869 ...
Page 125: ...Tetra Pak Hoyer 2 3 6 4 5 8 7 9 10 11 12 5 5 12 5 1 7 9 14 13 15 1 1 13040046 9 60 M 221869 ...
Page 145: ...Tetra Pak Hoyer 1 2 1 3 3 13040656 9 90 M 221869 ...
Page 150: ...Tetra Pak Hoyer CN 02 LA 02 Comet N Serial number ANNEXES ...