36
Recalling the unit price from a PLU:
Press P key. ”PLU” will be displayed.
Enter the required PLU number. (For ex.; press “7” & “1” keys to recall the unit weight
assigned to PLU 71).
WEIGHING WITH TARE
Place the tare weight on the weighing plate. Wait until the Equilibrium indicator is on. Tare
weight will be displayed.
Press Tare key. “dara” will be displayed for a second then “0.000” will be displayed. NET
indicator is ON. Tare symbol is flashing (only for LCD display). Tare has been weighed.
Place the product on weighing plate. Wait until Equilibrium indicator is on. Product’s net
weight will be displayed.
Empty the weighing plate. Wait until the Equilibrium indicator is on. NET and Tare indicators
are off. Tare is cancelled automatically.
Preset Tare:
Tare value can be entered by using numeric keypad.
Press EL key. “EL” will be displayed. Weight display is empty.
Press Tare key. “0.000” value will be displayed. (for 30 kg 2x3000 zero value is “0.000”)
Weight value can be entered by using numeric key pad “0”,”1”,…”9”. If 1 kg Tare value will
be set for 30 kg 2x3000 weighing instrument, “1.000” must be entered.
Press F key to set & save the tare value. In this mode, tare will not be cancelled when
weighing plate is empty.
NOTE
: Press Tare key twice for blocking the cancellation of tare. In this case, word “sabit” will be
displayed for a while and tare symbol (only for scales with LCD display) will be ON permanently. To
cancel tare, press Tare key when the weighing plate is empty.
Models with Tare symbol (for models with LCD displays);
Never ON : There is no tare.
FLASHING : When weighing plate is empty, tare will be cancelled automatically.
Always ON: Tare is fixed. Press Tare key to cancel it when weighing plate is empty.
TOTAL MEMORY FUNCTIONS
ATTENTION: If weighing instrument is EGE-M or EGE-LED and there is no printer, Total Memory Function
can not be used.
Total memory is used for adding more than one type of product and weight to previous calculated
product and weight. For this function, there are two keys M+, MR/MC on keyboard.
Adding to Total Memory:
Place the product on to the weighing plate. Wait until equilibrium indicator turns ON.
Enter the unit price of product.
Press M+ key. Weight and quantity are added to the memory. Related M indicator flashes.
Summary of Contents for EX10200006
Page 1: ...USERS GUIDE for WEIGHING PRICE COMPUTING COUNTING SCALES ...
Page 3: ...2 PRICE COMPUTING SCALES ...
Page 15: ...14 WEIGHING SCALES Except EKO ...
Page 26: ...25 WEIGHING SCALES EKO ...
Page 33: ...32 COUNTING SCALES ...
Page 129: ...ACHTUNG Nach Verlassen des Setup Menüs schalten Sie die Waage aus und wieder ein ...
Page 135: ...UWAGA Po wyjściu z menu ustawień należy wyłączyć wagę i włączyć ją ponownie ...