![background image](http://html.mh-extra.com/html/tem/ex10200006/ex10200006_user-manual_1085228031.webp)
30
Minimum value is 1, maximum value is 9. If a value is entered other than those, filter will use
its default value.
7.2 Average Length (50)
If the scale is approved model, it cannot be changed. Some models may not have this menu.
Minimum value is 10, maximum value is 50. If a value is entered other than those, filter will
use its default value.
7.3 Minimum Average Length (5)
If the scale is approved model, it cannot be changed. Some models may not have this menu.
Minimum value is 1, maximum value is 25. If a value is entered other than those, filter will
use its default value.
7.4 Filter Break Count Value
If the scale is approved model, it cannot be changed. Some models may not have this menu.
Minimum value is 70, maximum value is 2800. If a value is entered other than those, filter
will use its default value.
8. Calibration:
8.1 Calibration Coefficient
It can be changed only if the calibration key is ON.
8.2 Maximum Capacity
It can be changed only if the calibration key is ON.
8.3 Division (1)
0: 3000
1: 2 x 3000
2: 3 x 3000 (not valid for approved models)
3: 6000 / 7500 (not valid for approved models)
4: 12000 / 15000 (not valid for approved models)
6: 1500 (It can be changed only if the calibration key is ON.)
8.4 Load Cell Maximum Capacity
It can be changed only if the calibration key is ON.
8.5 Device Unit (1)
0: g
1: kg
2: ton
It can be changed if it is approved model.
8.6 Gravity (“G”) value of the location where scale is calibrated (9.8022)
It can be changed only if the calibration key is ON.
8.7 Gravity (“G”) value of the location where scale will be used (9.8006)
It can be changed only if the calibration key is ON.
Summary of Contents for EX10200006
Page 1: ...USERS GUIDE for WEIGHING PRICE COMPUTING COUNTING SCALES ...
Page 3: ...2 PRICE COMPUTING SCALES ...
Page 15: ...14 WEIGHING SCALES Except EKO ...
Page 26: ...25 WEIGHING SCALES EKO ...
Page 33: ...32 COUNTING SCALES ...
Page 129: ...ACHTUNG Nach Verlassen des Setup Menüs schalten Sie die Waage aus und wieder ein ...