1. Tare
1.1 Tare depends on stable equilibrium (On)
If it is approved, its default value is ON and it cannot be changed.
1.2 Cancel tare operation in negative net value (On)
Smaller tare than valid tare. (In negative net value). If it is approved, its default value is ON
and it cannot be changed.
2. Zero Setting:
2.1 Initial zero setting range control ±10% (On)
If it is approved, its default value is ON and it cannot be changed.
2.2 Zero setting key range control < 2% (On)
If it is approved, its default value is ON and it cannot be changed.
2.3 Zero setting depends on stability (On)
If it is approved, its default value is ON and it cannot be changed.
2.4 Automatic zero setting (On)
If the weight indication is negative for more than 5 seconds when the equilibrium indicator
is on, zero will be set automatically.
2.5 Automatic zero tracking (On)
If it is ON : Automatic zero tracking is active when the display is zero and stable.
If it is OFF : Automatic zero tracking is not active.
NOTE
: If there is tare, automatic zero tracking function will not work.
3. Stability:
3.3 Some functions depend on the stability (On)
If it is approved, its default value is ON and it cannot be changed.
6. Power Management Settings:
6.1 Empty Weighing Plate Indicator (On)
If it is ON : There will be a flashing dot on the display instead of weight value if scale is
powered by battery and left empty for 30 seconds. ( “------” will be displayed on LCD models)
If it is OFF : Does not function.
7. Filters:
7.1 Median Filter (5)
If the scale is approved model, it cannot be changed. Some models may not have this menu.
Summary of Contents for EX10200006
Page 1: ...USERS GUIDE for WEIGHING PRICE COMPUTING COUNTING SCALES ...
Page 3: ...2 PRICE COMPUTING SCALES ...
Page 15: ...14 WEIGHING SCALES Except EKO ...
Page 26: ...25 WEIGHING SCALES EKO ...
Page 33: ...32 COUNTING SCALES ...
Page 129: ...ACHTUNG Nach Verlassen des Setup Menüs schalten Sie die Waage aus und wieder ein ...
Page 135: ...UWAGA Po wyjściu z menu ustawień należy wyłączyć wagę i włączyć ją ponownie ...