71
Parameter
ID
Possible Parameter Value
Default Value
177 – COM TCP Link Mode Binary,
203 – DTO 1731, 204 –SE500, 10-11 – reserved)
COM2 Baudrate
122
0 – 115200
5
COM1 start byte
123
0 - 255
0
COM2 Mode
124
0 – 255 (5 - Silent, 13 - FM Log, 15 – NMEA,
97 - LLS, 98 - LCD, 99 - RFID, 100 - RFID M7,
101 - Garmin, 161 - COM TCP Link,
177 - COM TCP Link binary)
115200
TCP Link mode buffering
125
0/1 (0 – disable, 1 – enable)
0
COM1 end byte
126
0 - 255
0
COM2 start byte
127
0 - 255
0
COM2 end byte
128
0 - 255
0
COM1 Timestamp
151
0/1 (0 – disable, 1 – enable)
0
COM1 CMD ID
152
0 – 255
0
COM2 Timestamp
151
0/1 (0 – disable, 1 – enable)
10
COM2 CMD ID
152
0 – 255
3
Records saving/Sending
157
0/1/2 (0 – After GNSS fix,1 – Always, 2 – After
time synchronization)
0
SMS Event number
222-
231
String
„“
SMS event data min-max
300-
499
SMS Events
RS485 Activate
232
0/1 (0 – disable, 1 – enable)
0
RS485 Baudrate
233
0 – 115200
115200
RS485 Mode
234
0 – 255 (5 – Silent, 13 – Log mode, 15 – NMEA,
97 – LLS Mode, 161 – TCP link mode,
171 – Binary mode)
5
LLS 1-5 adress
256-
260
0,255
0
SIM1 GPRS APN
240
All character range
SIM1 GPRS USER
241
All character range
SIM1 GPRS PASS
242
All character range
SIM2 GPRS APN
243
All character range
SIM2 GPRS USER
244
All character range
SIM2 GPRS PASS
245
All character range
Tachograph ignition source
158
1/2/3/4
3
Tachograph device
159
0 - DTC0 1381, 1 - SE5000
0
Tacho web
160
0/1 (0 – disable, 1 – enable)
0
Tacho web domain
161
Maximum 56 Char
Empty
Tacho web port
162
0 - 65535
0
Tacho web start delay
174
0 – 255 (Min)
5
Bluetooth Power
164 0/1/2 (0-disable,1-enable hidden,2-enable visible)
0