Permanent I/O elements
(are always sent (with every record) to server if enabled)
Nr.
Property Name
Bytes
Description
44
Fuel Counter
4
Difference of generated impulses on two signal lines
45
Ignition
1
0 – ignition is off, 1 – ignition is on
46
RFID COM1
8
Displays activated RFID card ID from COM1
47
Total Odometer
4
Total odometer value km
48
RFID COM2
8
Displays activated RFID card ID from COM2
49
IMSI
8
IMSI code
50
CCID
24
CCID Code
51
LLS #1Fuel
2
Fuel level, measured by LLS sensor on COM2, in kvants
or liters.
52
LLS #1 temperature
1
Fuel temperature, measured by LLS sensor on COM2, in
degrees Celsius.
53
LLS #2 Fuel
2
Fuel level, measured by LLS sensor on COM2, in kvants
or liters.
54
LLS #2 temperature
1
Fuel temperature, measured by LLS sensor on COM2, in
degrees Celsius.
55
LLS #3 Fuel
2
Fuel level, measured by LLS sensor on COM2, in kvants
or liters.
56
LLS #3 temperature
1
Fuel temperature, measured by LLS sensor on COM2, in
degrees Celsius.
57
LLS #4 Fuel
2
Fuel level, measured by LLS sensor on COM2, in kvants
or liters.
58
LLS #4 temperature
1
Fuel temperature, measured by LLS sensor on COM2, in
degrees Celsius.
59
LLS #5 Fuel
2
Fuel level, measured by LLS sensor on COM2, in kvants
or liters.
60
LLS #5 temperature
1
Fuel temperature, measured by LLS sensor on COM2, in
degrees Celsius.
Table 22 EVENTUAL I/O elements list description
Eventual IO elements
(generated and sent record to server only if appropriate conditions are met)
Nr.
Property Name
Bytes
Description
55
CAN1 0
Varying
5
ID Specific data
56
CAN1 1
Varying
ID Specific data
57
CAN1 2
Varying
ID Specific data
58
CAN1 3
Varying
ID Specific data
59
CAN1 4
Varying
ID Specific data
60
CAN1 5
Varying
ID Specific data
61
CAN1 6
Varying
ID Specific data
62
CAN1 7
Varying
ID Specific data
63
CAN1 8
Varying
ID Specific data
64
CAN1 9
Varying
ID Specific data
65
CAN2 0
Varying
6
ID Specific data
66
CAN2 1
Varying
ID Specific data
5
CAN property length can vary depending on filter settings. Data can be sent as 1, 2, 4 or 8 byte property.
6
CAN property length can vary depending on filter settings. Data can be sent as 1, 2, 4 or 8 byte property.