11
Part name
Physical specification
Operation environment
USB
Mini USB socket
Battery charge current:
average 100 mA,
Rated current:
250 mA,
Internal fuse: 3A, 125V
Port1
RS232 or RS485 port channel 1 (RJ45
socket)
Port2
RS232 port channel 1 (RJ45 socket)
J1708
J1708 port channel
Figure 1 FMB630 view & dimensions in mm (tolerance ±2mm)
2.4
Technical Information about internal battery!
Ni-MH Rechargeable battery, 8.4V, 550 mA.
FMB630 operating time with internal backup battery depends on temperature, data
sending frequency (SMS and GPRS), and accumulator age, number of charge/discharge cycles.
For example:
In sleep mode a new FMB630 device, operating time approximately 5 hours
In deep sleep mode – 35 hours
Operating time for a new FMB630 device, working in normal mode (records are
being acquired every 10 sec. and sent in packets of 4 records every 60 sec.), is
approximately 2 h 10 min.
Charging temperature: 0 – 40 °C
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT
TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.