55
Eventual IO elements
(generated and sent record to server only if appropriate conditions are met)
Nr.
Property Name
Bytes
Description
67
CAN2 2
Varying
ID Specific data
68
CAN2 3
Varying
ID Specific data
69
CAN2 4
Varying
ID Specific data
70
CAN2 5
Varying
ID Specific data
71
CAN2 6
Varying
ID Specific data
72
CAN2 7
Varying
ID Specific data
73
CAN2 8
Varying
ID Specific data
74
CAN2 9
Varying
ID Specific data
75
Geofence zone 01
1
Event: 0 – target left zone, 1 – target entered zone
76
Geofence zone 02
1
Event: 0 – target left zone, 1 – target entered zone
77
Geofence zone 03
1
Event: 0 – target left zone, 1 – target entered zone
78
Geofence zone 04
1
Event: 0 – target left zone, 1 – target entered zone
79
Geofence zone 05
1
Event: 0 – target left zone, 1 – target entered zone
80
Geofence zone 06
1
Event: 0 – target left zone, 1 – target entered zone
81
Geofence zone 07
1
Event: 0 – target left zone, 1 – target entered zone
82
Geofence zone 08
1
Event: 0 – target left zone, 1 – target entered zone
83
Geofence zone 09
1
Event: 0 – target left zone, 1 – target entered zone
84
Geofence zone 10
1
Event: 0 – target left zone, 1 – target entered zone
85
Geofence zone 11
1
Event: 0 – target left zone, 1 – target entered zone
86
Geofence zone 12
1
Event: 0 – target left zone, 1 – target entered zone
87
Geofence zone 13
1
Event: 0 – target left zone, 1 – target entered zone
88
Geofence zone 14
1
Event: 0 – target left zone, 1 – target entered zone
89
Geofence zone 15
1
Event: 0 – target left zone, 1 – target entered zone
90
Geofence zone 16
1
Event: 0 – target left zone, 1 – target entered zone
91
Geofence zone 17
1
Event: 0 – target left zone, 1 – target entered zone
92
Geofence zone 18
1
Event: 0 – target left zone, 1 – target entered zone
93
Geofence zone 19
1
Event: 0 – target left zone, 1 – target entered zone
94
Geofence zone 20
1
Event: 0 – target left zone, 1 – target entered zone
95
Auto Geofence
1
Event: 0 – target left zone, 1 – target entered zone
96
Trip
1
1 – trip start, 0 – trip stop
97
Immobilizer
1
1 – iButton connected
98
Authorized driving
1
1 – authorized iButton connected
99
ECO driving/Green
driving type
1
1 – harsh acceleration, 2 – harsh braking, 3 - harsh
cornering
100
ECO driving/Green
driving value
1
Depending on ECO driving/Green driving type: if harsh
acceleration, braking and cornering – g*10 m/s
2
101
Over Speeding
1
At over speeding start km/h, at over speeding end
km/h
102
Excessive idling
1
1- idling detected, 0- idling ended
103
Jamming detection
1
1 – jamming start, 0 – jamming stop
104
Crash detection
1
1 – crash event occured
There are two types of operations with Permanent I/O elements: simple
monitoring and event generating. Monitoring method is used when current I/O
information needed with regular GPS coordinates. Event generating method is
used when additional AVL packet is needed when current value of I/O exceeds
predefined High and Low levels. I/O settings allow defining I/O event criteria.