![Teltonika FMB630 User Manual Download Page 59](http://html1.mh-extra.com/html/teltonika/fmb630/fmb630_user-manual_1084774059.webp)
59
“ setparam 1300 1,0,0,1,1”
(“ setparam 1300 <priority>,<HighLevel>,<LowLevel>,<Operand>,<AvgC
onstant>”)
Other I/O property elements can be configured in the same logic. All I/O element
parameters are listed below.
Table 29 I/O Elements
I/O Element Number
I/O element
parameters
I/O Element Number
I/O element
parameters
I/O#0 – Digital input 1
x300
I/O#29 – PCB Temp.
x324
I/O#1 – Digital input 2
x301
I/O#30 – Dallas ID 1
x325
I/O#2 – Digital input 3
x302
I/O#31 – Dallas Temp. 1
x326
I/O#3 – Digital input 4
x303
I/O#32 – Dallas ID 2
x327
I/O#4 – Digital output 1
x304
I/O#33 – Dallas Temp. 2
x328
I/O#5 – Digital output 2
x305
I/O#34 – Dallas ID 3
x329
I/O#6 – Digital output 3
x306
I/O#35 – Dallas Temp. 3
x330
I/O#7 – Digital output 4
x307
I/O#36 – Dallas ID 4
x331
I/O#8 – Analog input 1
x308
I/O#37 – Dallas Temp. 4
x332
I/O#9 – Analog input 2
x309
I/O#38 – Dallas ID 5
x499
I/O#10 – Analog input 3
X445
I/O#39 – Dallas Temp. 5
x500
I/O#10 – Profile
x310
I/O#40 – Dallas ID 6
x501
I/O#11 – Battery voltage
x311
I/O#41 – Dallas Temp. 6
x502
I/O#12 – Battery Current
x312
I/O#42 – Fuel Counter
x333
I/O#13 – GPS PDOP
x313
I/O#43 – Ignition
x334
I/O#14 – GPS HDOP
x314
I/O#44 – RFID ID
x335
I/O#15 – Ext. Voltage
x315
I/O#45 – Total Odometer
x519
I/O#16 – GNSS Status
x316
I/O#46 – RFID COM2
x520
I/O#17 – Movement sensor
x317
I/O#47 – IMSI code
x524
I/O#18 – Trip Odometer
x318
I/O#48 – CCID code
x525
I/O#19 – GSM Operator
x319
I/O#49 – LLS #1 temp.
x336
I/O#20 – Speed
x320
I/O#50 – LLS #1 meter
x337
I/O#21 – iButton ID
x321
I/O#51 – LLS #2 temp.
x338
I/O#22 – GSM Signal level
x322
I/O#52 – LLS #2 meter
x339
I/O#23 – Network Type
x447
I/O#53 – LLS #3 temp.
x340
I/O#24 – Acceleration
x448
I/O#54 – LLS #3 meter
x341
I/O#25 – Deceleration
x449
I/O#55 – LLS #4 temp.
x342
I/O#26 – Cell ID
x450
I/O#56 – LLS #4 meter
x343
I/O#27 – Area Code
x451
I/O#57 – LLS #5 temp.
x344
I/O#28 – Deep Sleep
x323
I/O#58 – LLS #5 meter
x345
6.3.8.4
SMS event configuration
To configure SMS event every value above should be separated with comma. For example,
configuring first SMS event from DIN1(AVLID 1) to send to first number in list, SMS should look like:
“ setparam 300 1,1,text”
(“ setparam 300 <avl id>, <number index>, <text>”)
Sms events are configurable for all profiles at ones.