114
Tachograph Vehicle Speed
reset
Tachograph Driver Card Presence
active
Driver1 States
active
Driver2 States
active
Driver1 Continuous Driving Time
active
Driver2 Continuous Driving Time
active
Driver1 Cumulative Break Time
active
Driver2 Cumulative Break Time
active
Driver1 Selected Activity Duration active
Driver2 Selected Activity Duration active
Driver1 Cumulative Driving Time
active
Driver2 Cumulative Driving Time
active
Send data with 0, if ignition is off (ID=904)
This parameter enables/disables data sending with 0 value, if ignition is off. 0 – disable, 1-
enable.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
1
U8
15.6
Parameters ID
When no I/O element is enabled, AVL packet comes with GPS information only. After
enabling I/O element(s) AVL packet comes with GPS information and also contains current
value(s) of enabled I/O element. AVL packet decoding is described in “FMXXXX Protocols”
document. List of available CAN bus data, parameter size, ID and value range you can find in
Table 30
Table 53 ACQUIRED LV- CAN200 PARAMETRS IO ID
Property
ID in AVL
packet
Property Name
Bytes
Description
30
LVCAN Speed
1
Value in km/h
31
LVCAN Acc Pedal
1
Value in persentages, %
33
LVCAN Fuel Consumed
4
Value in liters, L
34
LVCAN
Fuel
Level
(liters)
2
Value in liters, L
35
LVCAN Engine RPM
2
Value in rounds per minute, rpm
36
LVCAN Total Mileage
4
Value in meters, m
37
LVCAN
Fule
Level
(percent)
1
Value in percentages, %
12
LVCAN Program
Number
4
LVCAN Program Number
NOTE:
"Total Fuel Used“ is sent to server multiplied by 10.
Example: if value was 150.5 liters, „1505“ will be sent to server.