14
General Information
SeaBat Sonar UI - User Manual
Shutdown
.
The software and firmware will be halted followed by a power shutdown
Wake up
:
The SUI remembers the five most recent connections, and shows them
as ‘offline in the hardware pane’s sonar address combo box. After
selecting such an offline system from this address combo box and
checking the ‘Wake up’ checkbox the selected sonar will wake up. Even
when the power of the particular system is switched off. (Of course the
network connection should be present.)
Reboot
:
Reset the software and firmware.
Remote desktop
:
Start a Microsoft Remote Desktop session with the sonar computer.
3.3.1.3 Sonar Network Connections
This feature is only available for T20 and T50 sonars.
With the sonar network connections a connection with a sonar could
be established.
LAN1 and LAN2 refer to the processor network port.
A T-series processor (PSP) LAN1 port has a default setting of
10.11.10.1 and LAN2 a default setting of 10.11.10.2 with subnet mask
255.255.255.0 for both ports.
Select the ‘Restore factory settings’ checkbox in the Application
Settings dialog box to set the default settings for the ports.
Automatic IP address
:
Select the ‘automatic IP address’ checkbox when a DHCP network is
available. The processor will acquire an IP address from the DHCP
server. (This checkbox is by default unchecked).
Static IP address
:
For LAN 1 any IP address could be set.
For LAN 2 the IP address is fixed between the range of 10.11.10.2 and
10.11.10.9 An IP address must be set in this range.
The user is always able to make a connection by LAN 2 because the
IP address of LAN 2 is fixed. Only the user computer must be set in
the same LAN2 IP address range (10.11.10.xx).
By the computer name also a connection could be established. This is
only for advanced trouble shooting.
All changes made in this dialog have effect after
is pressed.