Behavior. The characters are entered into the math expression one at a time.
What do you want to do next?
Learn about the Math Setup controls.
Learn about averaging math waveforms.
Set up e-mail on trigger
Click Setup to access the E-mail on Event control window where you configure sending e-mail on events.
Enhanced bandwidth indicator.
Extinction ratio
Extinction ratio is the ratio of eye top to base. This measurement is only valid when the acquisition mode is set to WfmDB,
FastAcq is enabled, or the measurement is taken on a reference waveform saved in FastAcq mode.
Ext Ratio=pTopMean/pBaseMean
Extinction ratio decibel
Extinction ratio decibel is the ratio of eye top to base expressed in decibels.
This measurement is only valid when the acquisition mode is set to WfmDB, FastAcq is enabled, or the measurement is taken on
a reference waveform saved in FastAcq mode.
ExtdB=10 × Log(pTopMean/pBaseMean)
Eye base
Eye Base is the base value used in the extinction ratio measurements.
Eye Base = pBaseMean
Eye diagram
The eye diagram is a synchronized display of a data stream that shows signal levels and transition regions, typically over one
cycle.
The eye diagram has the appearance of an opened eye. Compared to a normal instrument display, the eye diagram generally
appears as an untriggered waveform. This is because on successive cycles the signal is high and then low. The areas of interest
are the transition regions and eye opening.
Eye height
Eye height is the measurement of the eye height in volts.
Eye Height = (pTopMean - 3 × pTopSigma) - (pBa 3 × pBaseSigma)
Oscilloscope reference
758
DPO70000SX, MSO/DPO70000DX, MSO/DPO70000C, DPO7000C, and MSO/DPO5000B Series
Summary of Contents for DPO2304SX
Page 1: ...Tektronix Digital Phosphor Oscilloscopes Printable Help P077006219 077 0062 19...
Page 2: ......
Page 3: ...Tektronix Digital Phosphor Oscilloscopes Printable Help www tek com 077 0062 19...
Page 32: ...Introduction xxviii DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 130: ...Cursor setups 98 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 198: ...MagniVu setup 166 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 212: ...Display setups 180 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 300: ...Math setups 268 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 408: ...MyScope setups 376 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 510: ...Trigger setups 478 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 548: ...Vertical setups 516 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 605: ...Utilities DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series 573...
Page 606: ...Utilities 574 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...
Page 920: ...Index 888 DPO70000SX MSO DPO70000DX MSO DPO70000C DPO7000C and MSO DPO5000B Series...