5-24
(3)
PI to P mode switch over by comparing
Acceleration command
.
When the
Acceleration command
is
less
than
Cn018
PI control is selected.
When the
Acceleration command
is
greater
than
Cn018
P control is selected.
As shown in diagram below:
PI/P-Mode Switching Condition
(Acceleration)
Speed
Acceleration Command
Cn018
(4)
PI to P mode switch over by comparing
Position Error value
.
When the
Position Error value
is
less
than
Cn019
PI control is selected.
When the
Position Error value
is greater than
Cn019
P control is selected.
As shown in diagram below:
(5) PI to P mode switch over by PCNT input contact
.
When the
PCNT input contact
is open
PI control is selected.
When the
PCNT input contact
is closed
P control is selected.
Note: Input contacts status “1” (ON) and “0” (OFF).
Please check 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.
Switch PI/P
by PCNT input contact
P control
PI control
Enable
Status of contact PCNT
1
0
PI control
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......