![Teco Electro Drives TSTA Series Installation And Operation Manual Download Page 151](http://html.mh-extra.com/html/teco-electro-drives/tsta-series/tsta-series_installation-and-operation-manual_1072528151.webp)
6-8
Parameter
Name & Function
Default Unit
Setting
Range
Control
Mode
Chapter
Analog monitor output 1, Offset adjustment
Cn027
Analog monitor output zero offset can be adjusted by
parameter.
Cn027
as below.
4
x40
mV
-250
│
250
ALL 5-6-9
Analog monitor output 2, offset adjustment
Cn028
Analog monitor output 2, zero offset can be adjusted by
parameter.
Cn028.
See diagram for Monitor 1 above.
4
x40
mV
-250
│
250
ALL 5-6-9
Reset parameters.
Setting Explanation
0 Disabled
★
Cn029
1
Reset all Parameters to default ( Factory
setting)
0 X
0
│
1
ALL 5-6-10
Servo motor model code
★
Cn030
Servo model code can be display and checked with
parameter dn-08, refer
3-2-2 dn-08
table for more
information.
Attention
:
Before operate your servo motor., check this
parameter setting is compatible for servo drive and
motor. If there has any incompatible problem contact
supplier for more information.
Default
X X ALL
3-2-2
Cooling fan running modes
(Available for TSTA-50 & TSTA-75)
Setting Explanation
0
Auto-run by internal temperature sensor.
1
Run when Servo ON
2 Always
Running.
Cn031
3 Disabled.
0 X
0
│
3
ALL 5-6-8
Speed feed back smoothing filter
Cn032
Restrain sharp vibration noise by the setting and this
filter also delay the time of servo response.
500 Hz
1
│
1000
Pe
Pi
S
5-3-12
Speed Feed-forward smoothing filter
Cn033
Smooth the speed feed-forward command.
40 Hz
1
│
100
Pe
Pi
5-4-6
Torque command smoothing filter
Cn034
Restrain sharp vibration noise by the setting and this
filter delay the time of servo response.
0 Hz
0
│
1000
ALL 5-2-7
Panel display content selection
Select display content for LED panel for power on status.
Setting Explanation
0
Display data set and drive status parameter. Refer
3
-
1
Cn035
1
│
19
Display Un-01 ~ Un-19 content. Refer 3-2-1 for
more information.
Ex
:
Set Cn035=1, when power on it display the
actual speed of motor. (content of Un-01)
0 X
0
│
19
ALL
3-1
3-2-1
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......