![Teco Electro Drives TSTA Series Installation And Operation Manual Download Page 75](http://html.mh-extra.com/html/teco-electro-drives/tsta-series/tsta-series_installation-and-operation-manual_1072528075.webp)
5-6
5-2-4 Definition of torque direction
In torque mode, torque direction can be defined by one of the following three methods.
(1) Input contacts
RS1
,
RS2.
(torque command CW/CCW selectable by programmable input)
(2) Parameter
Cn004.
(motor rotation direction )
(3) Input contact
TRQINV.
(reverse torque command)
Caution !
All 3 methods can be active at the same time.
User must ensure that correct selections are made for these three selections.
Input Contact
RS2
RS1
Description
Control
mode
0 0
Zero
torque
0 1
Rotation in the current torque command
direction
1 0
Reverse the current torque command direction
1 1
Zero
torque
T
Note: RS2 and RS1 contact status “1” (ON) and “0” (OFF).
Please check 5-6-1 to set the required high /Low signal levels ( PNP/NPN) .
Parameter
Signal
Name
Setting
Description
Control
mode
No.
Torque Control
Speed Control
0
Counter Clockwise (CCW)
Counter Clockwise (CCW)
1
Clockwise (CW)
Counter Clockwise (CCW)
2
Counter Clockwise (CCW)
Clockwise (CW)
Cn004
Motor rotation
direction (load end)
CCW
CW
3
Clockwise (CW)
Clockwise (CW)
S/T
Input contact TRQINV
Description
Control
mode
0
Rotation in current torque command
direction
1
Reverse torque command direction
T
Note: Input contacts status “1” (ON) and “0” (OFF).
Please refer to 5-6-1 to set the required high /Low signal levels ( PNP/NPN) selection.
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......