2-19
(3) CN1 Interface Circuit and Wire Mode:
The diagram below introduces all interface circuit of CN1 and wire-method of host controller.
(a) Digital input interface circuit (
IO1
):
Digital input interface circuit can be operated by relay or collector transistor circuit. The relay should be the low
electric current, in order to avoid the faulty contacting. External voltage: 24V.
Internal 24V Power
External 24V Power
IG24
DC24V
5.6K
Ω
SON
Servo Driver
i
=4.3mA
IP24
DICOM
CN1-45
CN1-47
CN1-49
(b) Digital Output Interface Circuit(
IO2
):
When using external power, please attention to the power polarity. Adverse polarity will case circuit damage.
Digital output is “Open Collector”. The maximum of external voltage is 24V; and the maximum electric current is
10mA.
Internal 24V Power
External 24V Power