5-10
5-3-1 Selection for speed command
In Speed control, input contacts SPD1 and SPD2 can be used for selecting one of the two methods below
for setting speed limits.
(1) External Analog command (Default) : Analog signal is input from terminals SIN & AG (pins 26& 29 on
CN1)
(2) Internal speed command: Selection of Three presentable Limits according to the table below.
.
Input Contact SPD2 Input Contact SPD1
Speed Command
Control
Mode
0 0
External analog command
SIN(CN1-26)
0 1
Internal speed command 1
Sn201
1 0
Internal speed command 2
Sn202
1 1
Internal speed command 3
Sn203
S
Note: Input contacts status “1” (ON) and “0” (OFF).
Please check 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.
Diagram below shows the external analog speed command wiring:
Internal presetable speed limit parameters for speed command mode are listed below:
These preset limits apply to both CW & CCW directions.
Parameter
Name
Default
Unit
Setting range
Control mode
Sn201
Internal speed
command 1
100
Sn202
Internal speed
command 2
200
Sn203
Internal speed
command 3
300
rpm -3000~3000
S
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......