2-20
(c)
Pulse Command Input Interface Circuit(
IO3
):
Suggesting to use the input method of Line Driver to send the pulse command. The maximum input command
frequency is 500kpps. Using the input method of Open Collector will cause the decrease of input command
frequency, the maximum input command frequency is 200kpps. The servo provides only 24V power, and other
power should be prepared. Adverse polarity of power will cause the servo damage. The maximum of External
power (Vcc) is 24V limited. Input current is about 8~15mA. Please refer to the examples below to select
resistance. Please refer to 5-4-1 to check pulse input command timing.
Line Driver pulse command input
Open Collector pulse command input
The max. frequency of line driver type pulse command
is 500kpps
Maximum input command frequency of open collector is
200kpps
Open Collector (Internal 24V)
Open Collector – Selection of input Resistance
DC24V
1K
Ω
330
Ω
Servo Driver
2K
Ω
OPC
IP24
/Pulse
/Sign
Pulse
Sign
IG24
CN1-45
CN1-49
CN1-41
The maximum input command frequency of open
collector is 200kpps
External Power
Vcc=24V
R=2K
Ω
External Power
Vcc=12V
R=750
Ω
External Power
Vcc=5V
R=100
Ω
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......