5-65
5-6-2 Switch for the Control Mode
Set one of the programmable input terminals to MDC (Control mode) selection.
The input then will select the preset control mode, which is set by Parameter Cn001.
Selections are listed
below:
Parameter Name Setting
Description
Control
Mode
MDC Input off
MDC Input On
3
Position Control
(External Pulse Command)
Speed Control
4
Speed Control
Torque Control
★
Cn001
Control Mode
Selection
5
Position Control
(External Pulse Command)
Torque Control
ALL
New setting will become effective after re-cycling the power.
Please check 5-6-1 to setting the input contact required high /Low signal levels (PNP/NPN
selection).
5-6-3 Auxiliary Functions
Function of Input Contacts SON, CCWL and CWL can be set according to the list below:-
Parameter
Name
Setting
Description
Control Mode
0
Use input contact
SON
to switch Servo On
。
★
Cn002.0
SON
(Servo ON )
1
Servo on with Power on.
SON
input contact not required
.
ALL
0
CCWL
and
CWL(external limits) are effective.
CCW and CW rotation is inhibited by
CCWL&CWL.
Cn002.1
CCWL
and
CWL
(Counter Clockwise
&
Clockwise Limits)
1
CCWL
and
CWL(external limits) are
ineffective.
CCW&CW rotation is not limited by
CCWL&CWL.
ALL
New setting will become effective after re-cycling the power.
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......