![Teco Electro Drives TSTA Series Installation And Operation Manual Download Page 135](http://html.mh-extra.com/html/teco-electro-drives/tsta-series/tsta-series_installation-and-operation-manual_1072528135.webp)
5-66
5-6-4 Brake Mode
Brake function for servo motor and the external mechanical brake if it is used can be set according to the table
below. Set the brake mode as required for Servo off, Emergency Stop and CCW/CW rotation inhibit functions.
Parameter
Name
Setting
Description
Control
Mode
Dynamic Brake
Mechanical Brake
0 Disable
Disable
1 Disable
Enable
2 Enable
Disable
Cn008
Brake
Modes
3 Enable
Enable
ALL
Note!
When the CCW/CW Drive Inhibit occur, the Cn009 has the higher priority than Cn008.
Example:
If Cn008 is set to 0 or 1 which means (no Dynamic Brake).
BUT Cn009= 1 (with Dynamic Brake), then the dynamic brake will be effective( enabled).
5-6-5 Timing Diagram of Mechanical Brake
In applications with vertical loading, if the power is turned off, to prevent the load from falling
due to gravity, a servo motor with electro-mechanical brake can be used.
This servo drive provides a brake output (
BI)
which can be used for controlling the external brake.
Timing of brake output signal can be set by parameter
Cn003
(Output Time for electro-mechanical Brake).
Typical Circuit Diagram
CN
2
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......