5-8
5-2-7 Additional torque control functions
Torque Output Monitor
When the torque level in CW or CCW directions becomes greater than the value set in
Tn108
(torque level monitor value), the output contact
INT
is active.
Parameter
Name
Default
Unit
Setting range
Control mode
Tn108
Torque output monitor
level
100 %
0~300
ALL
Note: Input contacts status “1” (ON) and “0” (OFF).
Please check 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.
Torque Smoothing Filter
Torque vibration can be diminution by setting an appropriate value in Cn034 (Torque command smoothing
filter), In the other hand, this will cause a delay in the response time of the torque loop.
Parameter
Name
Default
Unit
Setting range
Control mode
Cn034
Torque smoothing
filter
0 Hz 0~1000 ALL