![Teco Electro Drives TSTA Series Installation And Operation Manual Download Page 165](http://html.mh-extra.com/html/teco-electro-drives/tsta-series/tsta-series_installation-and-operation-manual_1072528165.webp)
6-22
Parameter
Name & Function
Default Unit
Setting
Range
Control
Mode
Chapter
Internal Position Command 16-Pulse Number
Pn363
Please refer to
Pn318
0 pulse
-32767
│
32767
Pi 5-4-2
Internal Position Command 16-Move Speed
Pn364
Please refer to
Pn319
0 rpm
0
│
3000
Pi 5-4-2
Setting for HOME routine.
Setting Explanation
0
Once the home routine is activated, motor will s
for Home Position switch in 1
st
speed in
CCW
direction.
I
nput contacts
CCWL
or
CWL can be used as
Home Reference Switch.
Once Home reference switch is detected, then
Contacts
CCWL
and
CWL
will act as normal M
limits again.
Note:
When using this function,
Pn365.1
can not be s
or
2
.
Cn002.1 ( selection for CCWL and CWL
be set to set to 0.
1
Once the home routine is activated, motor will
search for Home
Position switch in 1
st
speed in
CW direction.
I
nput contacts
CCWL
or
CWL can be used as
the Home Reference Switch.
Once Home position is detected, then input
contacts
CCWL
and
CWL
will act as normal
max. limits again.
Note:
When using this function,
Pn365.1
can not be
set to
1
or
2
.
Cn002.1 ( selection for CCWL and CWL)
must be set to 0.
2
Once the home routine is activated , motor will
search for Home position switch in 1
st
speed in
CCW direction
and sets the Home
reference position as soon as the input contact
ORG is activated.
If
Pn365.1=2
, it will directly find the closest
Rising-Edge of
ORG
to be the Home position
(without a need for Home Reference),
then it stops in accordance with
Pn365.3
setting.
Pn365.0
3
Once the home routine is activated , motor will
search for Home
Position switch in 1
st
speed in
CW direction
and sets the reference Home position as soon
as the input contact
ORG is activated.
If
Pn365.1=2
, it will directly find the closest
rising -Edge of
ORG
to be the Home position
(without a need for Home reference),
then it stops in accordance with
Pn365.3
setting.
0 X
0
│
5
Pi
Pe
5-4-8
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......