5-51
(5)
Pn365.0=2.
After Starting HOME routine, run C
CW
in 1
st
preset high speed to search for HOME
Reference.(
ORG
).
Pn365.1=2
After Finding the HOME Reference, the Rising Edge of
ORG sets the
HOME Position.
Pn365.2
=
2
Input Contact
SHOME
Starts the HOME routine.
Pn365.3
=
0 Reverse search for
HOME position
1
1
Speed
Position
Input Contact ORG
Pn367 (2
nd
stage low speed)
Pn365.1=2
Pn365.3=0
Pn366 (1
st
stage high speed)
Pn365.2=2
Pn365.0=2
Input Contact SHOME
(6)
Pn365.0=3.
After Starting HOME routine, run
CW
in 1
st
preset high speed to search for HOME
Reference.(
ORG
).
Pn365.1=2
After Finding the HOME Reference, the Rising Edge of
ORG sets the
HOME Position.
Pn365.2
=
2
Input Contact
SHOME
Starts the HOME routine.
Pn365.3
=
0 Reverse search for
HOME position
1
1
Pn365.3=0
Pn367 (2
nd
stage low speed)
Position
Speed
Pn366 (1
st
stage high speed)
Pn365.1=2
Pn365.2=2
Input Contact ORG
Pn365.0=3
Input Contact SHOME
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......