5-12
Refer to the following diagrams:
Speed Command(rpm)
Input Voltage (V)
Bias Voltage
Input Voltage (V)
Bias Voltage
Adjusting Value
Speed Command(rpm)
5-3-4 Analog reference for speed command limit
A maximum limit for analog speed can be set by Sn218.
Parameter
Name
Default
Unit
Setting range
Control mode
Sn218
Analog speed
command limit
Rate rpm
x 1.02
rpm 100~4500
S
5-3-5 Encoder Signal Output
Servo motor encoder pulse signal can be output to a host controller to establish an external control loop.
Set the required encoder Pulse Per Revolution (PPR) in parameter Cn005.