4-2
4-1 Trial Operation Servo motor without Load
To carry out a successful trial run follow the steps below and ensure that drive wiring is correct and as specified.
1. Installation of servo motor.
Ensure that the motor is installed securely so that there is no movement and vibration during trial run.
2. Wiring.
Check servo drive
、
motor power connections and motor encoder connection.
No control signal wiring is required of this stage thus remove connector (CN1) from the servo drive.
3. Servo drive power.
Apply power to servo drive. If the display shows any Alarm message such as graph below then refer to Alarm
contents of chapter 8 to identify the cause.
AL-14 is caused by Input terminals
CCWL (Counter clockwise Limit)
and
CWL (Clockwise Limit)
being activated
at the same time.
See (the default setting of high or low input logic state according to the description in section 5-6-1 ).
Because of the alarm, the servo can not operate normally.
Set the parameter
Cn002.1=1
to disable the drive limit function temporarily during trial run period.
In order to prevent potential damage,prior to trial run ensure that the driven
mechanism, couplings and belts etc are disconnected from the motor.
Warning!
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......