5-34
5-4-2 Internal Position Command
In internal position command mode, 16 preset position commands can be set by parameters
(
Pn317~Pn364
), and can be activated by use of input contacts
POS1 ~ POS4.
Preset positions are programmable and can be selected according to the table below
:
Position
Command
POS4 POS3 POS2 POS1
Position
Command
Parameter
Position
Speed
Parameter
Rotation Number
Pn317
P1 0 0 0 0
Pulse Number
Pn318
Pn319
Rotation Number
Pn320
P2 0 0 0 1
Pulse Number
Pn321
Pn322
Rotation Number
Pn323
P3 0 0 1 0
Pulse Number
Pn324
Pn325
Rotation Number
Pn326
P4 0 0 1 1
Pulse Number
Pn327
Pn328
Rotation Number
Pn329
P5 0 1 0 0
Pulse Number
Pn330
Pn331
Rotation Number
Pn332
P6 0 1 0 1
Pulse Number
Pn333
Pn334
Rotation Number
Pn335
P7 0 1 1 0
Pulse Number
Pn336
Pn337
Rotation Number
Pn338
P8 0 1 1 1
Pulse Number
Pn339
Pn340
Rotation Number
Pn341
P9 1 0 0 0
Pulse Number
Pn342
Pn343
Rotation Number
Pn344
P10 1 0 0 1
Pulse Number
Pn345
Pn346
Rotation Number
Pn347
P11 1 0 1 0
Pulse Number
Pn348
Pn349
Rotation Number
Pn350
P12 1 0 1 1
Pulse Number
Pn351
Pn352
Rotation Number
Pn353
P13 1 1 0 0
Pulse Number
Pn354
Pn355
Rotation Number
Pn356
P14 1 1 0 1
Pulse Number
Pn357
Pn358
Rotation Number
Pn359
P15 1 1 1 0
Pulse Number
Pn360
Pn361
Rotation Number
Pn362
P16 1 1 1 1
Pulse Number
Pn363
Pn364
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......