![Teco Electro Drives TSTA Series Installation And Operation Manual Download Page 139](http://html.mh-extra.com/html/teco-electro-drives/tsta-series/tsta-series_installation-and-operation-manual_1072528139.webp)
5-70
Setting for the Power of External Regeneration Resistor
When using external regeneration resistor, the power value (Watts) must be set in parameter
Cn012.
Parameter
Name
Default
Unit
Setting Range
Control Mode
Cn012
Watts setting for
External Regeneration
Resistor
60 ~150
W
0~10000
ALL
Wiring for External Regeneration Resistor
When external Regeneration Resistor is used, must remove the link between
PC
and
P1
on
TB1
Terminal.
Then the resistor should be installed between terminals
P
and
PC
.
For safety, use of resistors with thermal protection is recommended.
The thermal switch contact can then be interlocked to disable drive or remove power if necessary.
Refer to connection diagram below:
When installing Regeneration Resistors care must be taken as the resistor absorbs the regeneration power,
and it is possible to generate the high temperatures above 100°C.
Provide the necessary cooling and use appropriate high temperature wires and ensure there has enough
space between regeneration resistor and other materials.
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......