![Teco Electro Drives TSTA Series Installation And Operation Manual Download Page 171](http://html.mh-extra.com/html/teco-electro-drives/tsta-series/tsta-series_installation-and-operation-manual_1072528171.webp)
6-28
Parameter Name
&
Function Default Unit
Setting
Range
Control
Mode
Chapter
DO-1
Setting Explanation
Signal
Functions
01
RDY
Servo Ready
02
ALM
Alarm
03
ZS
Zero Speed
04
BI
Brake Signal
05
INS
In Speed
06
INP
In Position
07
HOME
HOME
★
Hn514.0
★
Hn514.1
08
INT
In Torque
01 X
01
│
08
DO-1
Setting Explanation
0
Close, when the output is activated.
★
Hn514.2
1
Open, when the output is activated.
0 X
0
│
1
ALL 5-6-1
DO-2
★
Hn515
Plearse refer to
Hn514
002 X
001
│
108
ALL 5-6-1
DO-3
★
Hn516
Plearse refer to
Hn514
003 X
001
│
108
ALL 5-6-1
DO-4
★
Hn517
Plearse refer to
Hn514
006 X
001
│
108
ALL 5-6-1
New setting will become effective after re-cycling the power.
Warning!
If any of programmable Inputs of DI-1 ~ DI-13 are set for the same type of function
then the logic state selection ( NO or NC selection) for these inputs must be the same type.
Otherwise an Alarm will be displayed. AL-07 (Abnormal DI/DO programming).
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......