3-5
Step
Control Keys LED Display after Operation
Description
1 Power
On
On” power on “
Drive Status
parameter is displayed.
2
Pressing
MODE-Key
6 times, position parameter Pn 301 will
be displayed.
3
Use
INCREMENT- Key
to display Pn317.
4
To view the Pn317 preset press
ENTER-Key
for 2 seconds.
5
To move to the most significant digit press the
ENTER-Key
4 times.
6
Press
DECREMENT-Key
once to set the most significant digit
To 1. And press the
DECREMENT-Key
once again.
All 5 decimal points will light up to indicate a negative number.
7
To save the altered preset value, Press the
ENTER- Key
for 2
seconds until
“SET”
is displayed briefly and then
display is returned to parameter Pn 317.
Alarm Reset from the Keypad.
All alarm displays can be cleared from the keypad without a need for an external Alarm clear (Reset) signal.
Ex. Under voltage Alarm AL-01.
Step
Control Key LED Display after Opertion
Description
1 Alarm
Under voltage Alarm AL-01 is displayed.
2
To clear Alarm:-
Remove input contact
SON
(Servo On).
Then press
INCREMENT-Key and DECREMENT-Key
at the same time.
The display will show RESET briefly and then returns back to
parameter display.
Summary of Contents for TSTA Series
Page 1: ......
Page 12: ...1 6 1 4 2 Direction and Distance Fan Fan ...
Page 15: ......
Page 45: ......
Page 59: ......
Page 69: ......
Page 175: ......
Page 206: ...9 4 Dimension for TSTA 15 and TSTA 20 ...
Page 207: ...9 5 Dimension for TSTA 30 ...
Page 208: ...9 6 Dimension for TSTA 50 and TSTA 75 ...
Page 211: ...DIMENSION TSB 07 08 SERIES 9 9 ...
Page 214: ......
Page 215: ......
Page 218: ......