5-53
5-4-9 Other Position Function
In position (Position Complete)
As long as the position
error value
(counts) is less than the pulse counts set in
Pn307
(Position Complete value) then
INP output contact
will be activated.
Parameter
Name
Default
Unit
Setting Range
Control
Mode
Pn307 Position
Complete
value 10 pulse 0~50000
Pi/Pe
Pn307
Position Complete Value
Speed
Position Incorrect Value
pulse
Speed Command Motor Speed
INP Statue
1
0
Note: Input contacts status “1” (ON) and “0” (OFF)
Please check 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.
Position error alarm
When the Position error value is greater than the preset pulse value of
Pn308
(Positive position error level) or
Pn309
(Negative position error level) this will generate
AL-11
(
Position error
) signal.
Parameter
Name
Default
Unit
Setting Range
Control
Mode
Pn308
Positive position error level
50000
pulse
0~50000
Pi/Pe
Pn309
Negative position error level
50000
pulse
0~50000
Pi/Pe