RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.15
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
To speed up the troubleshooting procedure, check the state of the power indicator LEDs
on the various circuit boards.
(1)
Slightly lift the Faston connectors on the machine power inlet socket. Place the tester probes
across the live and neutral pins on the same connector. The measured voltage should be
approximately 220 VAC/110 VAC.
(2)
Check if the
LEDs
1
and
2
(+5Vdc and +12Vdc), on the ARM board are on.
(3)
Check if the
LEDs
H6
and
H3
(+5Vdc and +12Vdc)on the
ALE
driver are on, and LEDs
H2
and
H3
fot
AT UL
driver.
(4)
Check if the main voltage (220Vac/110Vac) is on the pins
1
and
2
of the
J1
connectors of the
ALE
and
AT UL
driver.
(5)
Check the continuity of the power supply signals on the
TRM19
and
TRM20
cables, by
referring to paragraph: 2.7. “Cables” and replace what’s defective.
Summary of Contents for EXCITE Run 500
Page 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Page 2: ......
Page 4: ......
Page 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Page 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Page 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Page 60: ......
Page 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Page 148: ......
Page 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Page 218: ......
Page 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Page 230: ......
Page 233: ......