RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.44
Dove il raggio indica la distanza nedia di ricezione durante l’esercizio (con una precisione di
circa ± 10 cm – 4” inches).
(3)
Check that the cardio receiver has been assembled properly as described in the procedure:
7.9. “
HS/HR reciever (salutron 8500) disassembly
”.
(4)
To check for electromagnetic noise near the machine, use Test Box Excite as detailed here
below. You can use one of the following cables
ELT-16
(0WC00518AB),
CBQ-28
(0WC00390AC) or
TRM-28
(0WC00336AC) as connection cable.
The circuit lights the LED for each heart beat and/or disturbance received: in this way it is
possible to determine whether there is any interference, and identify its sources.
(5)
Check the battery power level, using a tester if possible. Otherwise use a receiver or another
reference machine to check the operation up to a distance of about 90 cm from the receiver.
HFU
Receiver
TEST BOX
EXCITE
HR receiver
Connection
cable
Summary of Contents for EXCITE Run 500
Page 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Page 2: ......
Page 4: ......
Page 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Page 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Page 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Page 60: ......
Page 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Page 148: ......
Page 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Page 218: ......
Page 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Page 230: ......
Page 233: ......