RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 3.10
3.1.14.1.
Fans
There are 2 fans powered with 24 Vdc used to cool down the ALE driver.
3.1.14.2.
Breaking resistor
It is a 150 Ohm used by the ALE driver board to dissipate the energy produced by the motor when
it is working as a generator.
3.1.15.
P
OWER SUPPLY BOX
It is a box that contains:
•
Power entry socket;
•
ON-OFF switch;
•
2 circuit breakers that check the overload on line and neutral;
•
a mutual inductance.