RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.28
6.10.
THE DISPLAY SHOWS “PRESS A KEYS…”
This error message can be caused by:
•
loss of communication between the lower and upper assemblies;
•
the user has pressed the emergency button;
•
detective emergency button: the micro switch is opened.
To In order to reinstate normal operation, simply press any key. If communication between the
upper and lower assemblies is not immediately re-established, the message will remain on the
display while the machine continues trying for 30 seconds, after which the “THE EQUIPMENT IS
BLOCKED” message will appear.
The machine keeps count of the attempts to reinstate communication by incrementing the
COM.FAULT parameter, which can be viewed using the procedure described in paragraph 9.4.4.3