Proline Promass F 500 EtherNet/IP
Technical data
267
Temperature tables
Observe the interdependencies between the permitted ambient and fluid
temperatures when operating the device in hazardous areas.
For detailed information on the temperature tables, see the separate document
entitled "Safety Instructions" (XA) for the device.
Storage temperature
–50 to +80 °C (–58 to +176 °F)
Climate class
DIN EN 60068-2-38 (test Z/AD)
Degree of protection
Transmitter
• As standard: IP66/67, type 4X enclosure
• When housing is open: IP20, type 1 enclosure
• Display module: IP20, type 1 enclosure
Sensor
• As standard: IP66/67, type 4X enclosure
• With the order code for "Sensor options", option
CM
: IP69 can also be ordered
External WLAN antenna
IP67
Vibration resistance
Device version: Order code for "Sensor connection housing", option: A "Aluminum,
coated", B "Stainless" or C "Ultra-compact hygienic, stainless"
• Vibration, sinusoidal according to IEC 60068-2-6
– 2 to 8.4 Hz, 7.5 mm peak
– 8.4 to 2
000 Hz, 2 g peak
• Vibration broad-band random, according to IEC 60068-2-64
– 10 to 200 Hz, 0.01 g
2
/Hz
– 200 to 2
000 Hz, 0.003 g
2
/Hz
– Total: 2.70 g rms
Device version: Order code for "Sensor connection housing", option: L "Cast, stainless"
For medium temperature range: standard version
• Vibration, sinusoidal according to IEC 60068-2-6
– 2 to 8.4 Hz, 7.5 mm peak
– 8.4 to 2
000 Hz, 2 g peak
• Vibration broad-band random, according to IEC 60068-2-64
– 10 to 200 Hz, 0.01 g
2
/Hz
– 200 to 2
000 Hz, 0.003 g
2
/Hz
– Total: 2.70 g rms
Device version: Order code for "Sensor connection housing", option: L "Cast, stainless"
For medium temperature range: extended temperature version, high-temperature version
and low-temperature version
• Vibration, sinusoidal according to IEC 60068-2-6
– 2 to 8.4 Hz, 3.5 mm peak
– 8.4 to 2
000 Hz, 1 g peak
• Vibration broad-band random, according to IEC 60068-2-64
– 10 to 200 Hz, 0.003 g
2
/Hz
– 200 to 2
000 Hz, 0.001 g
2
/Hz
– Total: 1.54 g rms